a) Hospital Room Pressure Monitors and Controls

  • Accurate room pressure differential measurement for safety
    and standards compliance
  • Industry-leading sensor accuracy within ±0.00001 in H2O
  • 4.3 in. flush-mounted color touchscreen
  • Intuitive interface for simplified programming and monitoring
  • Seamless integration to BAS via BACnet® MS/TP, LonWorks®,
    and Modbus® communications
  • Digital interface module has audible and visual alarms to
    alert users of unsafe conditions
  • Multiple levels of password protection provides secure access
    to controller functions
  • No isolation mode disables alarms when room is used for
    non-infectious patients or is unoccupied
  • Optional remote keyswitch allows for secure switching
    of room modes
  • Onboard diagnostics assist with HVAC troubleshooting
  • Partner controllers with a fast-acting actuator for immediate
    response to prevent alarms
  • Plug-in terminal strips for fast and accurate wiring installation
  • Mounts in a standard depth electrical box to easily fit within
    a typical framed wall
  • Multifunction for VAC and IAQ applications
  • 2 x inputs for external probes
  • 4 x analogue outputs
  • 1 x RS485 interface for ModBus RTU protocol
  • Outputs diagnostic
  • Possibility to edit the channel names

b) Laboratory Fume Hood Monitoring & Control

  • Accurately measures average fume hood face velocity
  • Analog output provides additional information
  • Easy installation and calibration
  • Easy configuration using keypad
  • Large display provides detailed fume hood information
  • Surface or flush mount options available
  • Optional Flow Monitor available
  • Accurately measures average fume hood face velocity
  • Analog output provides additional information
  • Easy installation and calibration
  • Easy configuration using keypad
  • Large display provides detailed fume hood information
  • Surface or flush mount options available
  • Optional Flow Monitor available

c) Medical Grade Air Decontamination Unit

  • GENANO model 5250M
  • Max cleaning capacity ~ 500 m3 / h
  • Cleaning efficiency 99.5% of particles <0.003 μm
  • Gas removal Carbon filter 800g; 60mm
  • Overall dimensions: Width x height x length 600 x 1680 x 600 mm
  • Weight 91kg
  • Material Painted steel
  • Electricity consumption Manual model: 70- 150 W
  • Noise level 30–42 LpA (dBa)
  • Power supply 230 Vac / 50 Hz
  • Operating temperature + 5 ° C- + 60 ° C
  • Efficient and compact Air Decontamination Device for patient rooms, examination rooms, dentist’s practices and offices.
  • Requires very small floor space, and has a wall-mounting option.
  • Genano’s patented Non-Thermal Plasma Technology removes even nanoscale impurities.
  • It eliminates organic microbes such as viruses, bacteria and mold and also removes gaseous VOC compounds and smells.
  • Elixair duct filter supplements the existing air ventilation system.
  • The duct filter is highly effective, requires conjunctional installation in the fresh air duct, as it filters out the smallest of particles from the supply air, preventing them from entering the room.
  • The duct filter does not get clogged which guarantees a steady filtration efficiency.
  • Simple and low cost maintenance
  • Active carbon shall be replaced every 6-12 months
  • Very low energy consumption (71 W)
  • Nordic design – made in Finland
  • Color – white with silver legs and top
  • Wall or ceiling -mounted Genano XS is suited for cleaning air in spaces, where it can not or is not wanted to be
    placed on the floor.
  • This air decontamination unit can also be placed on level surfaces or it can be integrated
    as part of an existing air ventilation system

d) Surface Disinfection

  • Easy and quick to use
  • Modern, effective and natural method, without chemicals
  • No chemical residue in the air and thus no odour
  • No build up of germ resistance
  • Easy to clean thus easy installation and maintenance
  • Low operation costs due to low energy consumption, endurance and maintenance costs
  • Motion dedector as safety switch
  • Stainless steel ring as lamp protection and practical handle
  • Fast odour removal by ozone
  • Disinfection of air and surfaces
  • Environmentally friendly – no chemicals
  • Low operating and maintenance costs
  • Ease of use
  • Automatic disinfection of surfaces and air in wet rooms
  • Automatic odor neutralization
  • No use of chemicals
  • No development of resistance of germs
  • Low operating costs due to low power consumption, long service life and low maintenance costs
  • Movement switch as a safety switch
  • Automatic elimination of dangerous germs and bacteria without creating extra work
  • Relieves the strain on hygiene specialists in the hospital
  • Hospital energy consumption similar to conventional lighting
  • Lamps are easy to change
  • Always compliant with the radiation limits prescribed by legislation
  • Rapid odor elimination with ozone
  • Disinfection of air and surfaces
  • Environmentally friendly
  • Low usage and maintenance costs
  • Easy to use

e) On line monitoring

  • Multifunction for VAC and IAQ applications
  • 2 x inputs for external probes
  • 4 x analogue outputs
  • 1 x RS485 interface for ModBus RTU protocol
  • Outputs diagnostic
  • Possibility to edit the channel names
  • 2 inputs for interchangeable probes
  • Four visual and audible alarms
  • Two analogue outputs 0-5/10 V or 0/4-20 mA
  • Four RCR relays (option)
  • Ethernet communication (option) and RS485 MODBUS (option)
  • Alternating display of one to three parameters
  • One input for an interchangeable probe
  • Location for SPI-2 or MVA interchangeable board
  • Three audible and visual (dual-color LEDs) alarms
  • Three analogue outputs (4 wires) 0/5-10 V or 0/4-20 mA and three reverse relay
  • Measuring range measures CO2 from 0 to 20,000 ppm and temperature from 0 to 50°C
  • With or without 2-line 19-digits LCD display
  • Two relays
  • 0-5/10 V or 0/4-20 mA outputs
  • Quick and easy mounting with the 1/4 turn system with wall-mount plate
  • Stainless steel or polycarbonate probe
  • With or without 2-line 19-digits LCD display
  • 0-5/10 V or 0/4-20 mA outputs
  • Trend indicator
  • Two relays
  • Quick and easy mounting with the 1/4 turn system with wall-mount plate