Temperature Bath

Kaye HTR-420 High Temperature Dry Block Calibrator
- Operating range of 30 to 420°C with temp stability of up to 0.01°C and uniformity of up to 0.1°C
- Fast Heating and Cooling times
- Calibration of up to 48 thermocouple with Dry Block insert savings hours of time
- Dry Block inserts are designed to accommodate thermocouples, IRTD, ValProbe flexible/bendable as well as RF ValProbe probes
- Software interface for all existing Kaye products (IRTD, Validator 2000, Validator AVS, ValProbe and RF ValProbe software for automatic / manual calibrations
- Easy to use touch screen
- Universal Power Supply 100 – 240 VAC / 50 – 60 Hz
- Addition inserts available for calibrating specialty or process probes

Kaye LTR Cool Dry Block Calibrator
- –95 ºC to 140 ºC Ultra-Cool Dry Block Calibrator
- Stirling cooler technology: reaches –80 ºC in 60 min; –95 ºC in 80 minutes
- Temperature stability of ±0.015 ºC
- Actual Uniformity 0.05°C Full Range
- Software interface with Kaye Validator for automatic sensor calibration utility
- Custom block design to accommodate 2 reference probes (IRTD) and four inserts with three thermocouples per insert
- Conformance to Euramet/cg-13
- Ergonomics/industrial design with two carrying handles for portability
- Rubber insulator cap to prevent frost build up
- Weight: 16 kg (35 lbs.)

Kaye CTR Series ValProbe Temp. Calibration
- 120-minute cool-down time from 30 to -80°C
- Large capacity for multiple and different size sensors
- Stability and uniformity of ±0.03°C
- Indicates temperature to 0.01°C resolution
- Automates calibration when used with the Validator 2000
- Quiet operation

RH-CAL Portable Relative Humidity Calibrator
- RH Accuracy: ± 0.5%
- RH Range: 5% to 95%
- AT Accuracy: ± 0.2°C
- AT Range: 10°C to 50°C
- Temperature and RH controlled independently
- Automatic correction for mirror contaminants
- Certified measurements against NIST traceable standards
- Standard features, where others charge extra

Kaye IRTD 400 Intelligent RTD Secondary Standard
- Temperature range -195 to 420°C
- Accuracy over range ±0.025°C
- Resolution 0.001°C
- Sensor element 200 Ohm Platinum sensor
- Sheath material InconelTM 600
- Immersion depth 101.6mm (4″)
- Calibration Traceable to NIST or PTB; Recommended calibration period is 1 year
- Measurement rate 30 readings per second
- Ambient temperature range 0 to 60°C (32 to 140°F)
- Humidity Humidity 0 to 95% non-condensing
- Dimensions Overall length: 603mm (23.75″); Grip: 89mm x 32mm (3.5″ x 1.25″)
- Sensor sheath: 457mm x 6.35mm (18″ x 0.25″)

Kaye IRTD 400 Display
• Touch Screen 4.3″
• Display readings for up to two Kaye IRTD Reference probes in three resolutions
• Show Delta between the two IRTDs
• Choose a scan interval from 5 to 60 seconds
• Supports both types of IRTD Connector cables
• Specify one of three temperature units ( C, F, K)
• Supports the change IRTD settings (Address, Units)
• Support logging to data captured to internal Memory (for 1 IRTD, and for 2 IRTDs)
Humidity Calibrator

GH 500
- Calibration of several instruments simultaneously
- solid transport case
- Aluminium frame
- Multi-probe ventilated measuring chamber
- Portable instrument
- Interchangeable regulating probe
Pressure Calibrator

GP 500
- Specific connectors
- Larged backlighted display
- Configuration software 20 programs with adjustable generations
- Solid transport case
- Aluminium housing with adjustable carrying handle
Particle Count Calibration

- Provide repair and service such as regular on-site preventive machine
- Carry substantial spare parts for particle counter services to ensure minimal downtime
- Perform laser change without return products to oversea manufacturers
- Product Support :
- Airborne Particle Counter
- Gas Particle Counter
- Remote Air Particle Sensor
- Particle Spectrometers