• Pressure
  • Temperature & Relative Humidity
  • Air Velocity
  • Multifunction
  • IAQ

a) Pressure

  • Configurable intermediary ranges and software or DIP switch configuration
  • 0-10 V or 4-20 mA output
  • With or without 10-digits LCD display
  • “1⁄4 turn” system mounting with wall-mount plate
  • Housing with simplified mounting system
  • Solenoid valve for auto-calibration (only on CP111 model)

 

  • Measuring range: CP 211: -100 to +100 Pa, CP 212: -1,000 to +1,000 Pa, and CP 213: -10,000 to +10,000 Pa
  • Solenoid valve for auto-calibration (CP211/212)
  • 0-5/10 V or 0/4-20 mA outputs
  • Two relays
  • Automatic autozero
  • Quick and easy mounting with the 1/4 turn system with wall-mount plate

b) Temperature & Relative Humidity

  • Measuring range from 5 to 95% RH and from 0 to 50°C (ambient model) or from -20 to +80°C (duct, remote or standard model)
  • 0-10 V output or 4-20 mA output
  • With or without 10-digits LCD display
  • Housing with simplified mounting system
  • Software or DIP switch configuration
  • Quick and easy mounting with the 1/4 turn system with wall-mount plate
  • Stainless steel or polycarbonate probe
  • With or without 2-line 19-digits LCD display
  • 0-5/10 V or 0/4-20 mA outputs
  • Trend indicator
  • Two relays
  • Quick and easy mounting with the 1/4 turn system with wall-mount plate

c) Air Velocity

  • Measuring range from 0 to 30 m/s and from 0 to 50°C
  • Alternating display of air velocity and temperature
  • 0-10 V or 4-20 mA output
  • With or without 10-digits LCD display
  • “1⁄4 turn” system mounting with wall-mount plate
  • Housing with simplified mounting system
  • Measuring ranges: air velocity: from 0 to 30 m/s
  • Temperature: 0 to +50 °C
  • With or without 2-line 19-digits LCD display
  • Two relays
  • 0-5/10 V or 0/4-20 mA outputs
  • Adjustment certificate

d) Multifunction

  • Multifunction for VAC and IAQ applications
  • 2 x inputs for external probes
  • 4 x analogue outputs
  • 1 x RS485 interface for ModBus RTU protocol
  • Outputs diagnostic
  • Possibility to edit the channel names
  • Alternating display of one to three parameters
  • One input for an interchangeable probe
  • Location for SPI-2 or MVA interchangeable board
  • Three audible and visual (dual-color LEDs) alarms
  • Three analogue outputs (4 wires) 0/5-10 V or 0/4-20 mA and three reverse relay

e) IAQ

  • Measuring range measures CO2 from 0 to 20,000 ppm and temperature from 0 to 50°C
  • With or without 2-line 19-digits LCD display
  • Two relays
  • 0-5/10 V or 0/4-20 mA outputs
  • Quick and easy mounting with the 1/4 turn system with wall-mount plate
  • High accuracy
  • Long-term stability
  • Reliable measurements
  • Interchangeable, autolock connector