Heating, Ventilation, And Air Conditioning

 

a) Ventilation Instruments Testing

with local calibration support

  • 2 ft. x 2 ft. (610 mm x 610 mm) air capture hood/frame/base
  • Detachable micromanometer
  • Swirl X Flow Conditioner
  • (4) AA size rechargeable NiMH batteries
  • Multi-country AC adapter
  • 18 in. (46 cm) Pitot probe
  • (2) Static Pressure probes
  • 16 ft. (4.8 m) Neoprene tubing

with local calibration support

Compliant with the following standards:

  • EN13779 Ventilation for Buildings – Achieve a good air quality with acceptable installation and running costs
  • EN12237 Ventilation for Buildings – Ductwork Strenght and Leakage of Circular Sheet Metal Ducts
  • EN12237 Ventilation for Buildings – Test procedures with measuring methods
  • HVCA DW/143 Ventilation for Buildings – Guidance document for Ductwork leakage Testing
  • EUROVENT 2/2 Air Leakage Rate in Sheet Metal Air Distribution Systems
  • SMACNA Sheet Metal And Air Conditioning Contractors National Association
  • Accuracy is ± 2,5% of volume flow

with local calibration support

Velocity
– Range 0.25 to 30 m/s (50 to 6,000 ft/min)
– Accuracy ±1.0% of reading ±0.02 m/s (±4 ft/min)
– Resolution 0.01 m/s (1 ft/min)

Range
– LCA301 0.00399 – 90 m2 (0.043 – 900 ft2)
– LCA501 0 – 46.45 m2 (0 – 500 ft2)

with local calibration support

  • High accuracy over a wide velocity range [0–6000 ft/min (0–30 m/s)]
  • Simultaneously measures temperature and velocity
  • Measures humidity
  • Calculates volumetric flow and actual/standard velocity
  • Data logging and LogDat2TM downloading software included

Pressure

  • Differential Range -300 to 300 psi (-2,068 to 2,068 kPa)
  • Gauge Range -20 to 300 psi (-138 to 2,068 kPa)
  • (-40 to 610 in. Hg)
  • Resolution (best) 0.001 psi (0.01 kPa)
  • (0.01 in. Hg)
  • Accuracy1 ±1% of reading plus .072 psi
  • (0.5 kPa) (0.15 in. Hg)
  • Units psi, in. H2O, ft H2O, kPa, mm Hg, in. Hg,
  • m H2O, bar
  • Pressure Connection ¼” 37• flare fitting, Male

with local calibration support

  • Static/Differential Pressure
  • Range1 -28.0 to +28.0 mm Hg, -3735 to +3735 Pa
  • (-15 to +15 in. H2O)
  • Accuracy ±1% of reading ±1 Pa
  • (±0.01 mm Hg, ±0.005 in. H2O)
  • Resolution 0.1 Pa, 0.01 mm Hg (0.001 in. H2O)

with local calibration support

  • Hold/Min/Max functions
  • 5 to 95 %RH
  • -20 to +70°C
  • -40 to +70°C dew point

with local calibration support

Adjustable backlight
– Contact/optical selection

FUNCTIONS
– Contact / optical selection
– Selection of tachometry units
– Hold function
– Display of minimum and maximum values
– Configurable auto shut-off
– Backlight
– Hold-min-max function
– Selection of units

Optical type : 0-60 000 rpm
Contact type : 0 -20 000 rpm

with local calibration support

  • Hold/Min/Max Functions
  • Supplied with silicone tube (MP 110 and 111)
  • Supplied with cristal tube (MP 112 and 115)
  • Safety connectors (MP 112 and 115)
  • MP 110: ±1,000 Pa
  • MP 111: ±1,000 mmH2O
  • MP 112: ±2,000 mbar
  • MP 115: ±500 mbar
  • -50 to 800C
  • Optical D.S. 20.1
  • Dual laser sighting
  • Emissivity adjustable from 0.10 to 1.00 (pre-set at 0.95)
  • High / low alarm
  • Supllied with case
  • Measuring range from -50 °C to +850 °C
  • Spectral response: 8 – 14 µm
  • Optical: 30:1
  • Dual laser sighting: wave length: from 630 nm-670 nm
  • Emissivity: adjustable de 0.10 à 1.00 (pre-set at 0.95)
  • High/low alarm and thermocouple K probe
  • Measuring range from -50°C to +1850°C
  • Spectral response 8 – 14 µm
  • Optical: 50:1
  • Dual laser sighting: wave length 630-670 nm
  • Emissivity: adjustable from 0.10 to 1.00 (pre-set at 0.95)
  • High/low alarm and thermocouple K probe

with local calibration support

  • KT220 with KTHA Probe
  • Input for 1 universal probe
  • Free, downloadable basic software
  • Large storage capacity of 1 million points
  • Large easy to read 2-line display
  • Monitoring mode for detailed reporting outside of set points
  • 2 configurable set point alarms per channel

with local calibration support

  • KH 120/220 – KT 120/220
  • KTT 320
  • Laboratory
  • Up to 4 inputs for external probes
  • NTC or K, J, T thermocouple
  • -200 to +1,000°C
  • 5 to 95 %RH
  • 0 to 10,000 lux

with local calibration support

  • KH50
  • 16,000 measuring points
  • Measures two parameters simultaneously
  • Magnetic back for fast & simple mounting
  • Fast data download (1,000 points/second)
  • Free downloadable basic software
  • 1-Line LCD screen

with local calibration support

  • KTT220
  • Inputs for 2 thermocouple probes
  • Large easy to read 2-line display
  • Magnetic back for fast & simple mounting
  • Large storage capacity of 1 million points
  • Fast data downloading (18,000 points/second)
  • Monitoring mode for detailed reporting outside of set points

with local calibration support

  • KCC320
  • Wireless connection for smartphones & tablets (Android and iOS)
  • Record up to 4 parameters simultaneously
  • Large storage capacity of 2 milion points
  • Supplied with an anti-theft wall mount with lock
  • Large 2-line LCD screen
  • Free downloadable basic software

Configuration, data download and data processing

 

b) Indoor Air Quality

with local calibration support

  • ±500 Pa / ±2,500 Pa / ±10,000 Pa
  • ±500 mbar / ±2,000 mbar
  • Thermocouple: -200 to +1760°C
  • Pt 100: -200 to +600°C
  • Humidity: 3 to 98 %RH
  • CO: 0 à 500 ppm
  • CO2: 0 à 5,000 ppm
  • Air velocity: -5 to 35 m/s
  • Airflow: 0 to 99,999 m3/h
  • Gas leak detection: 0 to 10,000 ppm
  • Tachometry: 30 to 60,000 rpm

with local calibration support

  • High accuracy over a wide velocity range
  • Displays up to five measurements simultaneously
  • Optional “smart” plug-in probes, can measure: Temp, RH, CO, CO2, VOC, Pressure & Velocity probes
  • Large graphic display
  • Manual or continuous data logging
  • Name test IDs meaningful to you
  • Bluetooth printer capability

with local calibration support

  • Low-drift NDIR CO2 sensor for stable, accurate readings
  • Sampling function records multiple point measurements
  • Ergonomic, overmolded case design

with local calibration support

  • Low-drift NDIR CO2 sensor for stable, accurate readings
  • Sampling function records multiple point measurements
  • Ergonomic, overmolded case design
  • Temperature and relative humidity measurements help determine thermal comfort
  • Calculates percent outside air from either CO2 or temperature
  • Directly calculates dew point and wet bulb temperatures
  • Shows up to three parameters

with local calibration support

  • Low-drift NDIR CO2 sensor for stable, accurate readings
  • Temperature and relative humidity measurements help determine thermal comfort
  • Directly calculates dew point and wet bulb temperatures
  • Electrochemical sensor measures CO
  • Calculates % outside air from either CO2 or temperature
  • Displays up to three parameters
  • Logs up to 26,900 data points with key (4) measured parameters enabled
  • Sampling function records multiple point measurements

with local calibration support

  • CO : 0 to 500 ppm
  • CO2 : 0 to 5,000 ppm
  • -200 to +600°C
  • 3 to 98 %RH
  • 0 to 5 m/s
  • Measuring range: 0 to 10,000 lux and 0 to 929 fc
  • Easy to use
  • Hold function
  • Built-in probe
  • Auto shut-off: 20 minutes
  • Adjustment certificate
  • Detector of refrigerant gases and hydrogen (HFC, HCFC, Nidron 5…)
  • Visual and audible alarm
  • Manual and automatic self-calibration
  • Design avoids turbulence in unidirectional airflow and re-aspiration of tested air
  • Portable and easily positioned, they operate with long life, rechargeable batteries
  • All manuals are available on a USB key in six languages
  • Micro USB for data download and instrument configuration
  • New Data Management – CFR 21 Part 11 compliance

with local calibration support

  • Compliant with USP chapter 1116 and ISO 14698-1
  • IQ OQ validation protocols available
  • Over 40.000 l of air
  • Up to 100 memorised sampling cycles
  • Design avoids turbulence in unidirectional airflow and re-aspiration of tested air in accordance with ISO specifications
  • Total traceability
  • Fingertip calibration system control without opening
    the instrument
  • Easy calibration monitoring
  • Five Mass Ranges (PM1, PM2.5, PM4, PM10, & TSP).
  • Handheld Operation.
  • Sample History.
  • Low Cost w/ Data Logging.
  • Battery Powered.
  • 1-Year Warranty.