Living Environment & Workplace

a) HVAC Testing & Balancing

cl1

with local calibration support

  • 2 ft. x 2 ft. (610 mm x 610 mm) air capture hood/frame/base
  • Manometer with carrying case
  • (4) AA size rechargeable NiMH batteries
  • Multi-country AC adapter
  • 18 in. (46 cm) Pitot probe
  • (2) Static Pressure probes
  • 16 ft. (4.8 m) Neoprene tubing

with local calibration support

Compliant with the following standards:

  • EN13779 Ventilation for Buildings – Achieve a good air quality with acceptable installation and running costs
  • EN12237 Ventilation for Buildings – Ductwork Strenght and Leakage of Circular Sheet Metal Ducts
  • EN12237 Ventilation for Buildings – Test procedures with measuring methods
  • HVCA DW/143 Ventilation for Buildings – Guidance document for Ductwork leakage Testing
  • EUROVENT 2/2 Air Leakage Rate in Sheet Metal Air Distribution Systems
  • SMACNA Sheet Metal And Air Conditioning Contractors National Association
  • Accuracy is ± 2,5% of volume flow
cl2

with local calibration support

Velocity
– Range 0.25 to 30 m/s (50 to 6,000 ft/min)
– Accuracy ±1.0% of reading ±0.02 m/s (±4 ft/min)
– Resolution 0.01 m/s (1 ft/min)

Range
– LCA301 0.00399 – 90 m2 (0.043 – 900 ft2)
– LCA501 0 – 46.45 m2 (0 – 500 ft2)

with local calibration support

  • High accuracy over a wide velocity range [0–6000 ft/min (0–30 m/s)]
  • Simultaneously measures temperature and velocity
  • Measures humidity
  • Calculates volumetric flow and actual/standard velocity
  • Data logging and LogDat2TM downloading software included

 

b) Indoor Air Quality

cl16

with local calibration support

  • ±500 Pa / ±2,500 Pa / ±10,000 Pa
  • ±500 mbar / ±2,000 mbar
  • Thermocouple: -200 to +1760°C
  • Pt 100: -200 to +600°C
  • Humidity: 3 to 98 %RH
  • CO: 0 à 500 ppm
  • CO2: 0 à 5,000 ppm
  • Air velocity: -5 to 35 m/s
  • Airflow: 0 to 99,999 m3/h
  • Gas leak detection: 0 to 10,000 ppm
  • Tachometry: 30 to 60,000 rpm
cl20

with local calibration support

  • High accuracy over a wide velocity range
  • Displays up to five measurements simultaneously
  • Optional “smart” plug-in probes, can measure: Temp, RH, CO, CO2, VOC, Pressure & Velocity probes
  • Large graphic display
  • Manual or continuous data logging
  • Name test IDs meaningful to you
  • Bluetooth printer capability
cl15

with local calibration support

  • CO : 0 to 500 ppm
  • CO2 : 0 to 5,000 ppm
  • -200 to +600°C
  • 3 to 98 %RH
  • 0 to 5 m/s
cl14
  • Noise pressure level: LAF, LAS, max, min
  • Equivalent continuous level: LAeq, LCeq, max, min
  • Peak pressure level: LCpk, LZpk
  • Detection and peak counting: 135 dB, 137 dB, 140 dB
  • Daily sound exposure level: Lex,d
  • Sound exposure: EA,T : in Pa²h
  • DOSE
  • Supplied with calibration certificate and LDS 23 software
cl11
  • Class 2 sound level meter integratingaveraging with storage function
  • 30 to 130 dB
  • Frequency weighting A, C, Z
  • Weighted sound level L
  • Equivalent continous level Leq
  • Sound exposure level LE
  • Peak pressure level LpK
  • Supplied with calibration certificate and LDB 23 software
cl8
  • Class B luxmeter
  • Instantaneous measurement
  • Relative illuminance function
  • Evolution of illuminance according to weather conditions
  • Cartography of illuminance
  • Uniformity
  • Hold/Min/Max function
  • 0.1 to 200,000 lux
  • 0.01 to 18,585 fc
  • Supplied with LLX 200 software and calibration certificate
cl12
  • Class B luxmeter
  • Instantaneous measurement
  • Relative illuminance function
  • Evolution of illuminance according to weather conditions
  • Cartography of illuminance
  • Uniformity
  • Hold/Min/Max function
  • 0.1 to 200,000 lux
  • 0.01 to 18,585 fc
  • Supplied with LLX 200 software and calibration certificate
cl10
  • Measurement and spot check of solar power
  • Calculation of energetic exposure
  • Results saved when instrument is switched off
  • Hold/Min/Max functions
  • 1 to 1300 W/m2
  • 1 Wh/m2 to 500 kWh/m2
  • Supplied with calibration certificate
cl9
  • Detector of refrigerant gases and hydrogen (HFC, HCFC, Nidron 5…)
  • Visual and audible alarm
  • Manual and automatic self-calibration
cl7

with local calibration support

  • Hold/Min/Max functions
  • 5 to 95 %RH
  • -20 to +70°C
  • -40 to +70°C dew point
cl5

with local calibration support

Adjustable backlight
– Contact/optical selection

FUNCTIONS
– Contact / optical selection
– Selection of tachometry units
– Hold function
– Display of minimum and maximum values
– Configurable auto shut-off
– Backlight
– Hold-min-max function
– Selection of units

Optical type : 0-60 000 rpm
Contact type : 0 -20 000 rpm

cl6

with local calibration support

  • Hold/Min/Max Functions
  • Supplied with silicone tube (MP 110 and 111)
  • Supplied with cristal tube (MP 112 and 115)
  • Safety connectors (MP 112 and 115)
  • MP 110: ±1,000 Pa
  • MP 111: ±1,000 mmH2O
  • MP 112: ±2,000 mbar
  • MP 115: ±500 mbar
cl13
  • -50 to 800C
  • Optical D.S. 20.1
  • Dual laser sighting
  • Emissivity adjustable from 0.10 to 1.00 (pre-set at 0.95)
  • High / low alarm
  • Supllied with case
cl18

with local calibration support

  • KTH 350 – KTR 350
  • Up to 2 inputs for external probes
  • Pt 100 external probes
  • -100 to +400°C
  • 0 to 100 %RH
cl17new

with local calibration support

  • KH 120/220 – KT 120/220
  • KTT 320
  • Laboratory
  • Up to 4 inputs for external probes
  • NTC or K, J, T thermocouple
  • -200 to +1,000°C
  • 5 to 95 %RH
  • 0 to 10,000 lux
cl19

Configuration, data download and data processing

cl22

with local calibration support

  • Airflow rate 100 l/min
  • Programmable volume of aspirated air from 1 to 1999
  • Sampling cycle record
  • Delay start
  • Digital visual display with indication of number of l/min air, date, operator and location
  • Measure aerosol concentrations corresponding to PM1, PM2.5, Respirable, or PM10 size fractions
  • Lightweight and portable
  • Manual and programmable data logging functions
  • Single point data logging capability
  • Handheld unit
  • Aerosol concentration range 0.001 to 150 mg/m3

 

Healthcare

a) Genano-Air Decontamination Unit

genano_png
  • Capture all particle sizes down to nanosized particles (1 nm = one millionth of a millimeter)
  • Eliminate microbes, such as viruses and bacteria
  • Delivers an impressive amount of ultra-pure air, up to 500 m3 in an hour.
  • Modern and versatile premium air decontamination unit.
  • Cleaning capacity: max. 500 m3/h
  • Operating voltage: 200–240 V, 50/60 Hz
  • Power consumption: 90–260 W
  • Cleaning efficiency: 99,5 %
  • Usage temperature: +5…+60 °C
  • Size (w x d x h mm): 600 x 600 x 1680
  • Weight: 91 kg
  • Installation: Mobile *
  • Unit has pivoting wheels for ease of movement

 

b) On line monitoring

cl27
  • Measurement ragne -100 to 100pa
  • 1 input for probe

 

C) HVAC & Air Quality testing meters

cl24

with local calibration support

  • From 0.300μm particle counter with (6 channels)
  • 1.00CFM flow rate
cl25

with local calibration support

  • 2 ft. x 2 ft. (610 mm x 610 mm) air capture hood/frame/base
  • Manometer with carrying case
  • (4) AA size rechargeable NiMH batteries
  • Multi-country AC adapter
  • 18 in. (46 cm) Pitot probe
  • (2) Static Pressure probes
  • 16 ft. (4.8 m) Neoprene tubing
cl26

with local calibration support

  • Airflow rate 100 l/min
  • Programmable volume of aspirated air from 1 to 1999 l
  • Sampling cycle record
  • Delay start
  • Digital visual display with indication of number of l/min air, date, operator and location